Model Number |
dry type transformer Non-encapsulated Transfomer |
SG(B)9 series: Heat resistance grade is Grade H: no-load loss is 10% lower than that of national standard; on-load loss is
10% lower than that of national standard; the noise is 10-20dB lower than that of national standard; the designed service
life is 30 years. SG(B)10 series: Heat resistance grade is Grade H: no-load loss is 20% lower than that of national standard; on-load loss is
15% lower than that of national standard; the noise is 15-30 dB lower than that of national standard; the design life is 30
years.
Functional Features
1. Safe and environment-friendly insulation system For SG (B) series of transformers, the insulation system based on the NOMEXå ìÂÂÂÂì paper is adopted. NOMEXå ìÂÂÂÂì paper is world
recognized high quality electric insulation material so SG series of transformers have excellent electric and mechanical
performance. Moreover, NOMEXå ìÂÂÂÂì paper is nontoxic, non-combustion-supporting and radiation-resistant. The reclaim of the
transformer is easy after use; copper wire and core can be recycled to be used to really to be green product.
2. Low loss, less partial discharge, and more stable performance Small volume, lightweight, low local discharge. The power frequency breakdown field strength of NOMEX å ìÂÂÂÂìÂÂÂÂpaper is 20- 40kV
/mm. The relative dielectric constant is close to that of air. Thus the electric field distribution becomes more reasonable
and the partial discharge is effectively reduced. NOMEXå ìÂÂÂÂì paper itself does not absorb water and it efficiently obstructs
external humid gas and performance is more steady and reliable after adopting vacuum pressure dipping paint. They are a new
generation environment-friendly products featuring low loss and low noise.
3. Strong overload capability NOMEXå ìÂÂÂÂì paper belongs to Grade C insulation materials, it remains good electric and mechanical performance when heat
resistance temperature reaches up to 220å ìÂÂÂÂì We use it as insulation material of Grade H SG (B)transformers at l80 å ìÂÂÂÂìÂÂÂÂand
improve the overload capability of transformers.
4. Reliable running and easy maintenance HV of SG (B) transformer is pie winding in the case of high voltage and foil winding in case of low voltage. After being
processed with vacuum pressure paint-dipping process, it has stronger capability of bearing abrupt short circuit. No crack
occurs when running and maintenance is not necessary. The overall running cost is low. Flexible design is not restricted by
the absence of dies. It can be designed according to any specification required by the customers. And perfect temperature
protection control system can be equipped so as to provide reliable guarantee for the safe running of transformers.
Keywords:transformer circuit,output transformer,transformer manufacturer,transformer calculations,transformers
|